Operation and Maintenance 27
Caution
Removal of the wrong power supply can threaten the security of stored
data. Use the indicators on the rear panel of the T5 to be certain that the
correct power supply is being removed.
Power Supply Removal
Follow this procedure below to remove a power supply module.
1. Unfasten the three captive screws that retain the supply module in the chassis. Refer to Figure 3-1 for
the location of these screws.
Figure 3-3 Power Supplies
2. Use the handle on the module to pull the supply assembly from the chassis. The module docking
connector will disengage from the chassis connector.
3. Replace the power supply module as soon as possible and make sure that the module connector mates
firmly with the chassis connector.
4. Reattach the three captive screws to secure the supply module.
Fan Removal
Follow this procedure to remove and replace a chassis-mounted fan. The power supply fans are an integral
part of the power supply modules and are not field-replaceable.
Power Supply
Captive Retaining
Screws